Hermetically sealed direct current electromagnetic relay with one circuit changeover contact.
It is applied to switch double current electric circuits.
Technical data and operating factors
MAIN ELECTRICAL DATA
Design | Operating voltage, V | Action voltage at 298К (+25oС), V, max | Coil resistance at 298К (+25oС), Оhm |
РС4.569.421-00.,-04.,-05.,-09.,-12. РС4.569.421.-01.;-06.;-13. РС4.569.421-02.,-07. РС4.569.421-03.,-08. | 27 + 9- 5 18 + 2 12 + 4- 2 6 + 2- 1 | 18.5 12.2 7.2 3.8 | 1900 + 285- 380 800 + 160 270 + 40.5 65 + 6.5- 9.75 |
Switching modes | ||||||
Switching range | Switching ranges current, А | Switching ranges current, А | Switching ranges current, А | Number of switching cycles. max | ||
Current, A | Voltage V | At Aver. Temper. | Also At 353к (+85oС) | |||
10-6 - 0.001 0.001 - 0.05 0.001 - 0.1 0.01 - 0.1 - 1.0 1- 6 similar relay 7- 48 similar relay Coil -29 1- 5 similar relay 6- 36 similar relay | 0.05 - 10 6 - 36 6 - 150 6 - 100 6 - 36 20 - 36 20 - 36 20 - 36 16 - 20 16 - 20 | Act. τ≤15 ms Act. Act. Act. Induc. Induc. Induc. Induc. Induc. | dir. dir. dir.. 50 Hz Dir. Dir. Dir. Dir. Dir. Dir. | 10 5 10 ≤5 10 10 10 1 10 10 | 105 2.5·103 105 5·104 105 105 104 104 105 104 | 2.5·104 1.25·103 2.5·104 1.25·104 2.5·104 2.5·104 2.5·103 2.5·103 2.5·104 2.5·103 |
![]() |